Double Pipe Heat Exchanger Design (DHex) 1.0
Step by step thermal design calculations of double pipe heat exchangers
DHex is a software tool that is made to demonstrate the chemical design calculations of Double pipe (hairpin) Heat Exchangers.The software will do all the thermal calculations involved in the design and will generate a summary of all results..etc
WeBBusterZ Engineering SoftwarePublisher:
Demo, $59.99 to buy Licence:
WindowsOS:
dhexdemo.exe - 5.99MBFile-Size:
March 18, 2006 Date Added:
New ReleaseDouble Pipe Heat Exchanger Design (DHex) Release status:
Double Pipe Heat Exchanger Design (DHex) 1.0 Description:
DHex is a software tool that is made to demonstrate the chemical design calculations of Double pipe (hairpin) Heat Exchangers.The software will do all the thermal calculations involved in the design and will generate a summary of all results, List of main functions:
+Step by step calculation
+Support S.I Units and English (U.S) Units of mesurement.
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!).
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Ability to calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement.
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Differance, Number of Hairpins,Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers
+Duty Calculation, Clean and Design Overall heat transfer coefficient calculations.
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units and Thermal Capacity ratio calculation +Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
+Export Results summary to Microsoft Excel
+Save/Load results. Generate/Print a summary of results. For more information visit http://www.webbusterz.com or http://www.webbusterz.net.
+Step by step calculation
+Support S.I Units and English (U.S) Units of mesurement.
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!).
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Ability to calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement.
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Differance, Number of Hairpins,Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers
+Duty Calculation, Clean and Design Overall heat transfer coefficient calculations.
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units and Thermal Capacity ratio calculation +Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
+Export Results summary to Microsoft Excel
+Save/Load results. Generate/Print a summary of results. For more information visit http://www.webbusterz.com or http://www.webbusterz.net.
Free Download Double Pipe Heat Exchanger Design (DHex) 1.0 now!
Double Pipe Heat Exchanger Design (DHex) 1.0 Tags:
heat exchanger double pipe hairpin heat exchangers thermal design calculations
heat exchanger double pipe hairpin heat exchangers thermal design calculations
Double Pipe Heat Exchanger Design (DHex) 1.0 system requirements:
Windows operating system, 20MB Free space
Windows operating system, 20MB Free space
Audio & Multimedia
Business
Accounting & Finance
Calculators & Converters
Databases & Tools
Helpdesk & Remote PC
Inventory & Barcoding
Investment Tools
Math & Scientific Tools
Office Suites & Tools
Other
PIMS & Calendars
Project Management
Vertical Market Apps
Communications
Desktop
Development
Education
Games & Entertainment
Graphic Apps
Home & Hobby
Network & Internet
Security & Privacy
Servers
System Utilities
Web Development
Business
Accounting & Finance
Calculators & Converters
Databases & Tools
Helpdesk & Remote PC
Inventory & Barcoding
Investment Tools
Math & Scientific Tools
Office Suites & Tools
Other
PIMS & Calendars
Project Management
Vertical Market Apps
Communications
Desktop
Development
Education
Games & Entertainment
Graphic Apps
Home & Hobby
Network & Internet
Security & Privacy
Servers
System Utilities
Web Development